Skip to content
FIELD NOTESWhy this view exists / what to try / what I learned
WHY

Compaction, moisture, dust, vibration. The four numbers an Engineer of Record audits. Without instrumentation the only defense in a dispute is anecdote, which is no defense at all.

WHAT TO TRY

Watch sensors tinted cat yellow or red. Those are in WATCH or ALARM state against their spec. The 30-point sparkline on each card shows the most recent drift. Click another site at the bottom to compare.

WHAT I LEARNED

Every sensor needs a spec attached. ASTM D6938 for density. Standard Proctor for compaction. EPA NAAQS for PM2.5. USBM RI 8507 for PPV. A number without a reference is noise. A number with a reference is evidence.

< Back to Operations
Dirt Sensors / ATX-SBX-001

Starbucks North Austin / live

6 sensors. Density and compaction against Standard Proctor. PM2.5 against EPA NAAQS. PPV against USBM RI 8507.

LIVEnow
Sensors
6
instrumented
Alarms
0
exceed threshold
Watches
4
approaching threshold
OK
2
within band
Weather (LIVE NWS)
83FSE 5mph
Partly Cloudy
Density
Density A1
Pad A
OK
133.05lb/ft3target 132
ASTM D6938 nuclear gauge
Density
Density A2
Pad A
OK
133.67lb/ft3target 132
ASTM D6938 nuclear gauge
Moisture
Moisture A
Pad A
WATCH
10.72%target 12.5
ASTM D2216 oven-dry vs probe
Compaction
Compaction A
Pad A
WATCH
93.18%target 95
Standard Proctor relative
Dust PM2.5
PM2.5 East fence
Perimeter
WATCH
33.59ug/m3target 18
EPA 24h PM2.5 NAAQS 35 ug/m3
RTK rover
RTK base rover
Site
WATCH
2.17cmtarget 1.4
Rover horizontal precision

Density curves are the only honest receipt for compaction. The probe does not lie.