Skip to content
BRIEFTerraFirma/ Robot Ranch MCC
00:00:00Z
< Back to Operations
Dirt Sensors / TAY-RTC-014

Taylor Retreat Center / live

12 sensors. Density and compaction against Standard Proctor. PM2.5 against EPA NAAQS. PPV against USBM RI 8507.

LIVEnow
Sensors
12
instrumented
Alarms
0
exceed threshold
Watches
2
approaching threshold
OK
10
within band
Weather (LIVE NWS)
85F
Sunny
Density
Density CA-1
Cut Zone A
OK
130.14lb/ft3target 132
ASTM D6938 nuclear gauge
Density
Density CA-2
Cut Zone A
OK
130.04lb/ft3target 132
ASTM D6938 nuclear gauge
Density
Density FB-1
Fill Zone B
OK
131.78lb/ft3target 132
ASTM D6938 nuclear gauge
Moisture
Moisture FB
Fill Zone B
OK
13.44%target 12.5
ASTM D2216 oven-dry vs probe
Compaction
Compaction FB
Fill Zone B
OK
98.41%target 95
Standard Proctor relative
Compaction
Compaction AR
Access Road
WATCH
93.24%target 95
Standard Proctor relative
Slope deviation
Slope incl AR-S1
Access Road
OK
0.55degtarget 0
Slope deviation from design
Slope deviation
Slope incl DET-S2
Detention
OK
0.21degtarget 0
Slope deviation from design
Dust PM2.5
PM2.5 SW fence
Perimeter
OK
24.7ug/m3target 18
EPA 24h PM2.5 NAAQS 35 ug/m3
Dust PM2.5
PM2.5 NE fence
Perimeter
WATCH
31.38ug/m3target 18
EPA 24h PM2.5 NAAQS 35 ug/m3
Vibration PPV
PPV neighbor monitor
Adj Property
OK
0.48ipstarget 0.5
USBM RI 8507 transient PPV
RTK rover
RTK base rover
Site
OK
1.38cmtarget 1.4
Rover horizontal precision

Density curves are the only honest receipt for compaction. The probe does not lie.